Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 198
Filter
1.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520232

ABSTRACT

ABSTRACT Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. Results: Altogether, 116 eyes of 58 patients were analyzed. The patients' mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson's correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord μ. The mean actual and apparent chord μ were 226.21 ± 128.53 and 278.66 ± 123.90 μm, respectively, with a mean difference of 52.45 μm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. Conclusions: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well.


RESUMO Objetivo: Comparar as diferenças entre a chord aparente μ e o chord real μ. Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone. Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord μ real foi 226,21 ± 128,53 μm e a média do chord μ média foi 278,66 ± 123,90 μm, com diferença média de 52,45 μm (p=0,01). A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam. Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.

2.
Rev. Headache Med. (Online) ; 15(1): 32-34, 2024.
Article in English | LILACS | ID: biblio-1538271

ABSTRACT

INTRODUCTION:Tonic pupil or Adie's pupil occurs due to parasympathetic denervation, and it is characterized by mydriasis with little or no response to light, with pupillary contraction to accommodation. It is caused by eye pathologies, such as infections, trauma, neoplasms, inflammatory diseases, and systemic diseases with autonomic dysfunction. Few cases have been reported of bilateral tonic pupils associated with migraine attacks. CASE REPORT: Our aimed to describe the case of a young female patient with a history of chronic migraine without aura, who presented acutely with bilateral pupillary mydriasis during a migraine attack, characterized as tonic pupil, and to discuss the possible causes of mydriasis during a migraine attack.


INTRODUÇÃO: A pupila tônica ou pupila de Adie ocorre devido à denervação parassimpática e é caracterizada por midríase com pouca ou nenhuma resposta à luz, com contração pupilar à acomodação. É causada por patologias oculares, como infecções, traumas, neoplasias, doenças inflamatórias e doenças sistêmicas com disfunção autonômica. Poucos casos foram relatados de pupilas tônicas bilaterais associadas a crises de enxaqueca. RELATO DE CASO: Nosso objetivo foi descrever o caso de uma paciente jovem, com história de enxaqueca crônica sem aura, que apresentou agudamente midríase pupilar bilateral durante uma crise de enxaqueca, caracterizada como pupila tônica, e discutir as possíveis causas da midríase durante uma crise de enxaqueca. ataque de enxaqueca.


Subject(s)
Humans , Male , Female , Mydriasis/classification , Tonic Pupil/prevention & control , Pupil/physiology , Headache/diagnosis , Migraine Disorders/complications , Eye
3.
International Eye Science ; (12): 77-81, 2024.
Article in Chinese | WPRIM | ID: wpr-1003510

ABSTRACT

Alzheimer's disease(AD)is a common degenerative disease of the central nervous system in which neuropathological changes precede cognitive dysfunction and behavioral impairment. Currently, early diagnosis of AD is based on invasive and expensive testing techniques that are difficult to use widely in the clinical setting. Therefore, there is an urgent need for new markers to detect AD at an early stage. The eye, as an extension of the brain, has been found to show earlier onset of ocular pathologic changes in patients with AD compared to brain pathologic changes, such as retinal structural abnormalities, visual dysfunction, retinal abnormal protein accumulation, choroidal thickness changes, decreased corneal nerve fiber density, deposition of abnormal Aβ proteins in the lens, and pupillary light decreased sensitivity of response, etc. This article reviews the ocular pathologic changes in AD patients in recent years to provide new ideas for the early clinical diagnosis of AD.

4.
Indian J Ophthalmol ; 2023 May; 71(5): 2251-2253
Article | IMSEAR | ID: sea-225062

ABSTRACT

Insufficient pupillary dilatation is a significant challenge during cataract surgery, as it increases the risk of various intraoperative complications. Implantation of toric intraocular lenses (TIOL) is particularly difficult in eyes with small pupils, as the toric marks are provided in the periphery of the IOL optic, making the visualization of the same difficult for proper alignment. Attempts at visualizing these marks using a second instrument such as a dialler or iris retractor lead to additional manipulations in the anterior chamber resulting in increased chances of postoperative inflammation and intraocular pressure rise. A new intraocular lens (IOL) marker to guide the implantation of TIOLs in eyes with small pupils is described, which can potentially be beneficial in achieving accurate alignment of toric IOLs in small pupils, without the need for additional manipulations, thus improving safety, efficacy, and success rates of TIOL implantation in these eyes.

5.
Arq. neuropsiquiatr ; 81(5): 452-459, May 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447406

ABSTRACT

Abstract Background Pupil reactivity and the Glasgow Coma Scale (CCS) score are the most clinically relevant information to predict the survival of traumatic brain injury (TBI) patients. Objective We evaluated the accuracy of the CCS-Pupil score (CCS-P) as a prognostic index to predict hospital mortality in Brazilian patients with severe TBI and compare it with a model combining CCS and pupil response with additional clinical and radiological prognostic factors. Methods Data from 1,066 patients with severe TBI from 5 prospective studies were analyzed. We determined the association between hospital mortality and the combination of CCS, pupil reactivity, age, glucose levels, cranial computed tomography (CT), or the CCS-P score by multivariate binary logistic regression. Results Eighty-five percent (n = 908) of patients were men. The mean age was 35 years old, and the overall hospital mortality was 32.8%. The area under the receiver operating characteristic curve (AUROC) was 0.73 (0.70-0.77) for the model using the CCS-P score and 0.80 (0.77-0.83) for the model including clinical and radiological variables. The CCS-P score showed similar accuracy in predicting the mortality reported for the patients with severe TBI derived from the International Mission for Prognosis and Clinical Trials in TBI (IMPACT) and the Corticosteroid Randomization After Significant Head Injury (CRASH) studies. Conclusion Our results support the external validation of the CCS-P to predict hospital mortality following a severe TBI. The predictive value of the CCS-P for long-term mortality, functional, and neuropsychiatric outcomes in Brazilian patients with mild, moderate, and severe TBI deserves further investigation.


Resumo Antecedentes A reatividade pupilar e o escore da Escala de Coma de Glasgow (ECC) representam as informações clínicas mais relevantes para predizer a sobrevivência de pacientes com traumatismo cranioencefálico (TCE). Objetivo Avaliar a acurácia da ECC com resposta pupilar (ECC-P) como índice prognóstico para predizer mortalidade hospitalar em pacientes brasileiros acometidos por TCE grave e compará-lo com um modelo combinando ECC e resposta pupilar com fatores prognósticos radiológicos. Métodos Foram analisados dados de 1.066 pacientes com TCE grave de 5 estudos prospectivos. Foi determinada a associação entre mortalidade hospitalar e a combinação de ECC, reatividade pupilar, idade, níveis glicêmicos, tomografia computadorizada (TC) de crânio ou o escore ECC-P por regressão logística binária multivariada. Resultados Oitenta e cinco por cento (n = 908) dos pacientes eram homens. A média de idade foi de 35 anos e a mortalidade hospitalar geral foi de 32,8%. A AUROC (em português, Curva Característica de Operação do Receptor) foi de 0,73 (0,70-0,77) para o modelo utilizando o escore ECC-P e de 0,80 (0,77-0,83) para o modelo incluindo variáveis clínicas e radiológicas. O escore ECC-P mostrou acurácia semelhante na previsão da mortalidade relatada para pacientes com TCE grave derivados dos estudos International Mission for Prognosis and Clinical Trials in TBI (IMPACT, na sigla em inglês) e Corticosteroid Randomization After Significant Head Injury (CRASH, na sigla em inglês). Conclusão Nossos resultados apoiam a validação externa da ECC-P para prever a mortalidade hospitalar após um TCE grave. O valor preditivo da ECC-P para mortalidade a longo prazo, resultados funcionais e neuropsiquiátricos em pacientes brasileiros com TCE leve, moderado e grave precisam ser investigados.

6.
Indian J Ophthalmol ; 2023 Mar; 71(3): 1023-1024
Article | IMSEAR | ID: sea-224920

ABSTRACT

Small pupil is a well-known risk factor for causing cataract surgery complications such as vitreous loss, anterior capsular tear, increased inflammation, and an irregular pupil shape. Because all currently available pharmacological approaches of dilating the pupil before or during cataract surgery cannot guarantee the result, the surgeon sometimes resorts to the use of mechanical pupil-expanding devices. However, these devices can increase the overall surgical cost and operative time. Very frequently, a combination of the two is needed; thus, we present the Y-shaped chopper designed by the authors, which serves the purpose of managing the intra-operative miosis and allows simultaneous nuclear emulsification.

7.
Indian J Ophthalmol ; 2023 Jan; 71(1): 57-61
Article | IMSEAR | ID: sea-224776

ABSTRACT

Purpose: To study the effect of pupil dilation on a biometric iris recognition (BIR) system for personal authentication and identification. Methods: A prospective, non?randomized, single?center cohort study was conducted on patients who reported for a routine eye check?up from November 2017 to November 2019 (2 years). An iris scanning device “IRITECH?MK2120U” was used to initially enroll the undilated eyes. Baseline scans were taken after matching with the enrolled database. All eyes were topically dilated and matched again with the enrolled database. The Hamming distance (a measure of disagreement between two iris codes) and recognition status were recorded from the device output, and eyes were evaluated by slit?lamp ophthalmoscopy with special emphasis on pupil shape, size, and texture. Results: All 321 enrolled eyes matched after topical dilation. The pupil size had a significant effect on Hamming distance with a P value <0.05. There were no false matches. A correct recognition rate of 100% was obtained after dilation. No loss of iris texture or pupil shape was observed after dilation. Conclusion: A BIR system is a reliable method for identification and personal authentication after pupil dilation. Topically dilated pupils are not a cause for non?recognition of iris scans.

8.
Article | IMSEAR | ID: sea-217869

ABSTRACT

Background: In ophthalmology (OPD), cycloplegics or mydriatics were needed for doing correct refraction and evaluation of fundus on a daily basis. Aims and Objectives: The objectives of this study were to compare the clinical efficacy and systemic side effects of different dilutions of phenylephrine and tropicamide combinations drops on pupil dilatation and to measure and compare pulse rate and blood pressure before and after giving the drug. Materials and Methods: The present study is a hospital-based interventional study conducted among patients attending to OPD of Regional Eye hospital, Visakhapatnam during April 2012–August 2012. Eighty-one patients randomly allocated to two groups (41 patients in Group 1 and 40 patients in Group 2). Dilution of phenylephrine 5% and Tropicamide 0.8% mixture was applied to patients of Group A in both eyes and dilution of phenylephrine 2.5% and Tropicamide 0.4% mixture was applied to Group B patients in both eyes. Pupil diameter and pulse rate BP were measured and compared. Results: Mean age of Group 1 patients was 55.39 ± 11.47 and Group 2 was 49.95 ± 13.71. Among 36 males, 50% in Group 1 and 50% in Group 2 and among 45 females 51.1% in Group 1 and 48.9% in Group 2. Among both Group 1 and Group 2 patients, both left and right pupil size was significantly increased after application of dilutions, but there was more increase in the pupil size among Group 1 patients compared to Group 2 patients 15 min after and 30 min after application of drug. Conclusions: The combination of 0.8% tropicamide and 5% phenylephrine was effective compared to alternate application of 0.4% tropicamide and 2.5% phenylephrine for rapid and sustainable pupil dilatation for indirect ophthalmoscopy.

9.
Chinese Journal of Experimental Ophthalmology ; (12): 474-482, 2023.
Article in Chinese | WPRIM | ID: wpr-990870

ABSTRACT

Objective:To evaluate the effect of short-term topical administration of atropine eye drops with various concentrations and frequencies on eye safety in children.Methods:A double-blind randomized controlled trial was conducted.Sevevty-two children with ametropia or pre-myopia (72 eyes) were enrolled in Tianjin Medical University Eye Hospital from December 2020 to January 2022.The subjects were randomly divided into 0.01% atropine group, 0.02% atropine group and 0.04% atropine group according to a random number table, with 24 cases (24 eyes) in each group.Automatic refraction with an automatic computer optometry device, subjective refraction with a phoropter, intraocular pressure with a non-contact tonometer, axial length by optical biometrics, the amplitude of accommodation (AMP) by the push-up method, pupil diameter with pupilometer, near visual acuity at 33 cm with a standard logarithmic visual acuity chart, tear evaluation with Keratograph 5M and Ocular Surface Disease Index (OSDI) questionnaire survey were performed among all subjects.One drop of 0.01%, 0.02%, and 0.04% atropine was administrated to the study eye according to grouping, and the pupil diameter was measured every 10 minutes until the pupil did not enlarge three times, then the data after a single treatment of the three groups were recorded.After one-week application of the corresponding concentration of atropine eye drops once at night, the data after one-week treatment were recorded.For the next week, the application frequency of 0.01% and 0.02% atropine groups changed to once daily in the morning and evening, and 0.04% atropine group maintained once at night, then the data after two-week treatment were recorded.Data of the right eyes were analyzed.The changes in pupil diameter, AMP and other eye parameters before and after atropine eye drops of the three groups were compared.This study adhered to the Declaration of Helsinki and the study protocol was approved by the Ethics Committee of Tianjin Medical University Eye Hospital (No.2020KY[L]-51). All subjects and their guardians were fully informed of the method and purpose of this study before entering the cohort.Written informed consent was obtained from guardians.Results:Pupil diameters of 0.01%, 0.02% and 0.04% atropine groups were (5.59±0.48), (5.35±0.76) and (5.65±0.43)mm before treatment respectively, (7.00±0.68), (7.17±0.58) and (8.40±1.71)mm after a single treatment, (6.67±0.62), (6.56±0.65) and (7.60±0.69)mm after one-week treatment, (6.96±0.49), (7.04±0.53) and (7.60±0.36)mm after two-week treatment.There were significant differences in pupil diameter at different time points after treatment among the three groups ( Fgroup=9.430, P<0.001; Ftime=156.620, P<0.001). The AMP of 0.01%, 0.02% and 0.04% atropine groups were (12.94±3.02), (13.25±2.81) and (13.42±2.60)D before treatment respectively, (11.62±2.61), (11.53±2.06) and (9.64±1.93)D after a single treatment, (11.14±2.61), (11.33±2.33) and (8.30±1.18)D after one-week treatment, (9.99±1.81), (8.72±1.25) and (8.76±2.12)D after two-week treatment.There was no significant difference in the AMP among the three groups ( Fgroup=2.800, P=0.063). In the three groups, the AMP at different time points after treatment were significantly lower than that before treatment ( Ftime=61.400, P<0.001). There was no difference in spherical equivalent refraction, intraocular pressure, near visual acuity, axial length, first none-invasive tear break-up time, average none-invasive tear break-up time, tear meniscus height and OSDI score among the three groups ( Fgroup=0.030, 0.630, 1.420, 0.580, 0.140, 0.120, 0.340, 0.142; all at P>0.05). There were significant differences in spherical equivalent refraction, intraocular pressure, first none-invasive tear break-up time, average none-invasive tear break-up time, tear meniscus height and OSDI score at different time points between before and after medication among the three groups ( Ftime=12.560, 4.730, 4.720, 5.220, 3.720; all at P<0.05). Conclusions:Varying pupil dilation and AMP reduction occur after the use of different concentrations of atropine and are more severe at higher concentrations.Increased administration frequency of atropine is associated with more pupil dilation and AMP reduction, but there is no intolerable adverse effect.

10.
Chinese Journal of Experimental Ophthalmology ; (12): 338-343, 2023.
Article in Chinese | WPRIM | ID: wpr-990852

ABSTRACT

Objective:To explore the pupil size distribution of the Chinese myopic population under different mesopic conditions, and to analyze the possible influencing factors.Methods:A cross-sectional study was conducted.Two hundred and fourteen myopic patients (428 eyes) who underwent refractive surgery in Tianjin Eye Hospital from December 2018 to April 2019 were randomly selected.The patients were 17 to 45 years old, with an average age of (22.62±4.88) years old.The patients were divided into astigmatism <-1.5 D group (372 eyes) and astigmatism ≥-1.5 D group (56 eyes) according to their astigmatism measurements.The low mesopic pupil size (LMPS) (0.2 lx) was measured with the infrared Colvard pupillometer, and the high mesopic pupil size (HMPS) (6-12 lx) was obtained through the anterior Pentacam segment analyzer.The pupil size was compared between both eyes, different sexes and different astigmatism measurements.The relationship between pupil size and possible influencing factors, such as age, sex, spherical equivalent, spherical diopter, cylinder diopter, axis, mean keratometry(Km), and central cornea thickness was analyzed.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Tianjin Eye Hospital (No.201912). Written informed consent was obtained from each subject or their guardians.Results:The pupil sizes measured by the Colvard pupillometer and Pentacam were (6.806±0.776)mm and (3.312±0.540)mm, respectively.The pupil size of male subjects was (6.692±0.754)mm, which was larger than (6.668±0.792)mm of females, showing a statistically significant difference ( t=2.935, P=0.004). Under the high mesopic condition, the pupil size of astigmatism ≥-1.5 D group was lower than that of astigmatism <-1.5 D group, with a statistically significant difference ( t=2.611, P=0.009). Under the low mesopic condition, pupil size was negatively correlated with age and Km ( r=-0.213, -0.210; both at P<0.001). Under the high mesopic condition, pupil size was weakly positively correlated with cylinder power ( r=0.124, P=0.010) and was weakly negatively correlated with Km ( r=-0.142, P=0.003). The multiple linear regression analysis revealed that the LMPS=0.659×HMPS-0.019×age-0.084×Km+ 8.662.About 28% of pupil size under low mesopic conditions could be predicted by Pentacam.LMPS of ≤7 mm could be better predicted when the results were below 3.6 mm. Conclusions:Age and corneal curvature are influencing factors of mesopic pupil size.Older people with steep curvature have a smaller pupil.At high mesopic conditions, astigmatism affects pupil size.Pentacam measurements can predict LMPS to some degree but are not a substitute for dark-adapted pupil diameter.

11.
International Eye Science ; (12): 477-482, 2023.
Article in Chinese | WPRIM | ID: wpr-964252

ABSTRACT

AIM: To valuate the efficacy of 0.01% atropine for controlling myopia in children of different ages.METHOD: A randomized, double-blind, placebo control and single-center study was conducted. A total of 295 myopic children, aged 6~13 years, with myopia of -0.5D~-6.00D and astigmatism ≤2.0D, who admitted to our hospital from May 2019 to May 2020 were randomly assigned to experimental group(197 cases)and control group(98 cases)in a 2:1 ratio. Two groups were further divided into three subgroups according to age, 6~8 years old group(40/26 cases), 9~10 years group(84/34 cases), and 11~13 years group(73/38 cases). 0.01% atropine was administrated in the experimental group and placebo was administrated in the control group once before sleep. The changes of parameters were compared before and at 2wk, 3, 6, 9 and 12mo after treatment. Intraocular pressure, accommodation amplitude, best corrected distance and near visual acuity, pupil diameter and tear film were tested at 2wk. Cycloplegic refraction was assessed before treatment, and at 6 and 12mo after treatment.RESULTS: The spherical equivalent and axial length progression at 12mo after administration was -0.37±0.69D and 0.29±0.24mm in the experimental group, and -0.59±0.65D and 0.37±0.23mm in the control group(P=0.008, 0.006). In 6~8 years group, spherical equivalent and axial length progression between experimental and control group were not statistically significant(t=0.054, P=0.957; t=-0.623, P=0.536). In 9~10 years group, spherical equivalent and axial length progression between groups were statistically significant(t=2.056, P=0.042; t=-2.057 P=0.042). In 11~13 years group, spherical equivalent and axial length progression between groups were statistically significant(t=2.33, P=0.022; t=-2.424, P=0.017). The pupil was slightly dilated and the accommodation amplitude was decreased in experimental group, and the mean pupil diameter of the two groups was 3.94±0.79 and 3.16±0.48 mm respectively at 12mo after treatment(P<0.001). Other parameters and adverse event noted between groups were not statistically significant.CONCLUSIONS: 0.01% atropine is helpful to control the progression of myopia in children, which is well tolerated by adolescents. However, the effect of 0.01% atropine on the control of myopia for children aged 6~8 years is not enough. The findings suggest that increased concentration of atropine can be tried for 6~8 years old.

12.
International Eye Science ; (12): 867-872, 2023.
Article in Chinese | WPRIM | ID: wpr-972419

ABSTRACT

AIM:To explore the influence factors of the treatment zone diameter(TZD)and its correlation with axial length growth(ALG)after Paragon CRT orthokeratology.METHODS: Retrospective clinical study. The data of 226 myopic patients(226 eyes)wearing Paragon CRT orthokeratology from April 2020 to September 2022 were collect. The correlated factors of TZD after wearing lens for 1mo, and the relationship between the overlapping treatment zone/ pupil area ratio and the ALG after wearing lens for 1a were analyzed.RESULTS: After wearing lens for 1mo, the TZD was negatively correlated with central corneal thickness(CCT)and positively correlated with the flat corneal eccentricity. After wearing lens for 1a, the ALG of the small TZD group(0.25±0.18mm)was significantly smaller than that of the large TZD group(0.34±0.24mm, P=0.002), and the ALG of the small area ratio group(0.24±0.19mm)was significantly smaller than that of the large area ratio group(0.35±0.23mm,P&#x003C;0.001). Age and overlapping treatment zone area/pupil area ratio were significantly associated with the ALG in multivariate linear regression(all P&#x003C;0.05).CONCLUSION: The wearers with thicker CCT and smaller flat corneal eccentricity usually had smaller TZD, and both the TZD and the overlapping treatment zone area/pupil area ratio were correlated with the ALG.

13.
Indian J Ophthalmol ; 2022 Oct; 70(10): 3575-3578
Article | IMSEAR | ID: sea-224616

ABSTRACT

Purpose: We aimed to evaluate the normative pupillometry values and mean pupil dilatation speed in healthy individuals in different age groups in our study. Methods: The study group included 180 eyes of 90 healthy volunteers in different age groups. Group 1 consisted of 30 participants between the ages of 6 and 18, group 2 consisted of 30 participants aged 19–40, and group 3 consisted of 30 participants aged 41–75. Scotopic, mesopic, photopic, and dynamic measurements were taken with automatic pupillometry of Sirius Topographer (CSO, Firenze, Italy). The mean pupil dilation speed at the 18th second was calculated according to dynamic measurements. Results: Group 1 had a significantly larger pupil diameter than groups 2 and 3 in all static and dynamic parameters, and the mean pupil dilation speed was the highest among the groups (P < 0.001 for all static and dynamic parameters). In addition, group 2 had a significantly larger pupil diameter than group 3 (P < 0.001 for all static and dynamic parameters) and the mean pupil dilation speed was faster than group 3 (P = 0.027). Conclusion: We have presented the static and dynamic parameters and the mean speed of pupil dilatation at the 18th second with automatic pupillometry in healthy individuals in childhood, adulthood, and old age. More studies with higher participants and younger age children are needed.

14.
Arq. bras. oftalmol ; 85(5): 485-489, Sept.-Oct. 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1403445

ABSTRACT

ABSTRACT Purpose: To evaluate the effect of pupil dilation on intraocular pressure in preterm and term newborns. Methods: This prospective study involved 55 eyes of 28 preterm infants and 38 eyes of 20 term infants. The infants were divided into two groups according to their gestational ages at birth as follows: preterm group, <37 weeks and term group, ≥37 weeks. Pupil dilation was attained with tropicamide 0.5% and phenylephrine 2.5%. Intraocular pressure measurements were performed with Icare PRO (Icare Finland Oy, Helsinki, Finland) before and after pupil dilation. A paired t test was used to compare the measurements before and after pupil dilation. Results: The mean intraocular pressure change was -1.04 ± 3.03 mmHg (6.20/-11.40 mmHg) in the preterm group and -0.39 ± 2.81 mmHg (4.60/-9.70 mmHg) in the term group. A statistically significant difference in intraocular pressure was observed only in the preterm group after pupil dilation (p=0.01). Conclusion: An unexpected alteration in intraocular pressure in newborns may occur after pupil dilation, especially in preterm infants.


RESUMO Objetivo: Avaliar o efeito da dilatação da pupila sobre a pressão intraocular em recém-nascidos pré-termo e a termo. Métodos: Este estudo prospectivo envolveu 55 olhos de 28 bebês pré-termo e 38 olhos de 20 bebês a termo. Os bebês foram divididos em dois grupos, pré-termo e a termo, de acordo com a idade gestacional ao nascimento: grupo pré-termo <37 semanas; grupo a termo ≥37 semanas. A dilatação da pupila foi feita com tropicamida 0,5% e fenilefrina 2,5%. As medições da pressão intraocular foram realizadas com Icare PRO (Icare Finland Oy, Helsinki, Finlândia) antes e depois da dilatação da pupila. O teste t pareado foi usado para comparar as medidas antes e depois da dilatação da pupila. Resultados: A alteração média da pressão intraocular foi de -1,04 ± 3,03 mmHg (+6,20/-11,40 mmHg) no grupo pré-termo e -0,39 ± 2,81 mmHg (+4,60/-9,70 mmHg) no grupo a termo. Uma diferença estatisticamente significativa na pressão intraocular foi observada apenas no grupo pré-termo após a dilatação da pupila (p=0,01). Conclusão: Após a dilatação da pupila, pode ocorrer alteração inesperada da pressão intraocular em recém-nascidos, principalmente em bebês pré-termo.

15.
Indian J Ophthalmol ; 2022 Aug; 70(8): 3166
Article | IMSEAR | ID: sea-224560

ABSTRACT

Background: Surgeons often notice unexplained dilation of the pupil following an uncomplicated intra-ocular surgery. No definite line of treatment has been proposed for managing Urrets-Zavalia syndrome (UZS). The authors have previously documented the results of surgical pupilloplasty and have outlined this modality of treatment for cases with UZS. Purpose: To highlight the aspect of development of UZS post-operatively in the eyes following an intra-ocular surgery. Synopsis: The video highlights the aspect of prevalence of the persistently dilated pupil that is non-responsive to topical miotics. Apart from associated glare, these cases often have raised intra-ocular pressure because of appositional closure of the anterior chamber angle. Surgical pupilloplasty pulls the iris tissue centrally, eventually releasing the mechanical blockage and often breakage of the peripheral anterior synechias as demonstrated by intra-operative gonioscopy and anterior segment optical coherence tomography. Highlights: Performing a surgical pupilloplasty can resolve the UZS, and timely intervention can also prevent the development of secondary glaucoma because of fallback of the iris tissue on the structures of the anterior chamber angle.

16.
Rev. Méd. Inst. Mex. Seguro Soc ; 60(2): 129-133, abr. 2022. tab
Article in Spanish | LILACS | ID: biblio-1367108

ABSTRACT

ntroducción: la cirugía de catarata con implante de un lente intraocular es, hoy en día, el procedimiento quirúrgico más frecuente en todo el mundo. Su éxito depende de muchos factores, uno de los más importantes es el cálculo exacto del poder dióptrico del lente intraocular. Objetivo: comparar el cálculo del poder dióptrico del lente intraocular en los pacientes sin y con dilatación pupilar. Material y métodos: estudio longitudinal, en el que se determinó el cálculo del poder dióptrico del lente intraocular en pacientes con y sin dilatación pupilar. Las variables de estudio fueron: edad, género, ojo a estudiar, queratometría, longitud axial, profundidad de cámara anterior y poder dióptrico del lente intraocular. Se realizó estadística descriptiva y t de Student. Resultados: se estudiaron 37 pacientes, 23 mujeres y 14 hombres. La edad promedio fue de 68 ± 7.87 años. Se estudiaron 64 ojos, 30 fueron derechos y 34 izquierdos. Estadísticamente solo hubo diferencia significativa en K2 de la biometría ocular entre pacientes sin y con dilatación pupilar al obtenerse un valor de p ≤ 0.05. Conclusión: no existen cambios en el cálculo del poder dióptrico del LIO sin y con dilatación pupilar.


Background: Cataract surgery with intraocular lens implant is, nowadays, the most frequent surgical procedure in all the world. Its success depends on a lot of factors, one of the most important is the calculation of the exact dioptric power of intraocular lens. Objective: To compare the calculation of dioptric power of intraocular lens with and without dilatation in patients with cataract. Material and methods: Longitudinal study, the calculation of the dioptric power of the intraocular lens was determined in patients without and with pupillary dilation. The variables were age, gender, eye to study, keratometry, axial length, anterior chamber depth and dioptric power of the intraocular lens. Descriptive statistics and Student t test were performed. Results: There were 37 patients, 23 females and 14 males. The average age was 68 + 7.87 years. Sixty-four eyes were studied, 30 were right and 34 left. Statistically, there was only significant difference in K2 of the ocular biometry between patients without and with pupillary dilation when obtaining a value of p < 0.05. Conclusion: There are no changes in the calculation of the dioptric power of the Intraocular lens without and with pupillary dilation


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Cataract , Pupil , Dilatation , Lenses, Intraocular , Longitudinal Studies , Biometry/methods , Octogenarians
17.
Arq. bras. oftalmol ; 85(1): 25-29, Jan.-Feb. 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1350091

ABSTRACT

ABSTRACT Purpose: To evaluate and compare variations in pupillary diameter before and after cataract surgery by conventional phacoemulsification versus femtosecond laser assisted cataract surgery, using LDV Z8 (Ziemer Ophthalmic). We also evaluated the relationship between pupillary diameter and surgery time and ultrasound time. Methods: Prospective comparative study, carried out at the Center of Excellence in Ophthalmology, Brazil. We included 79 eyes of 67 patients with nuclear opacity. The patients were divided into the control and study groups, including those who underwent cataract surgery with manual phacoemulsification, and femtosecond laser assisted cataract surgery, respectively. All surgeries were performed by the same experienced surgeon. All patients received topical non-steroidal anti-inflammatory drugs on the day before surgery and the same mydriatic eye drops preoperatively. To quantify pupillary size, measurements were performed using a surgical compass: anterior to the phacoemulsification procedure and at the end of the surgery. In the study group, measurements after laser were added. Surgical time and phacoemulsification time were also analyzed. Results: No significant difference was found between the pre-femto × pre-phaco pupil size (8.69 ± 0.44 mm × 8.63 ± 0.72 mm; p=0.643), and the pupil size at the end of surgery (7.96 ± 0.98 mm × 7.78 ± 0.95 mm; p=0.480) and the mean time of surgery (p=0.780). However, in the femtosecond laser assisted cataract surgery group, a transient increase in pupillary diameter after laser treatment was observed, indicating a tendency for greater variation in the femto group. Conclusions: Although pupil size diameter was similar at the end of surgery, the femtosecond laser assisted cataract surgery group presented higher intraoperative pupil variation. The surgeon should be aware of pupil size diameter before surgery for better and safer performance of femtosecond laser assisted cataract surgery.


RESUMO Objetivo: Avaliar e comparar a variação do diâmetro pupilar antes e após a cirurgia de catarata por facoemulsificação convencional versus cirurgia de catarata assistida por laser de femtossegundo, usando o LDV Z8 (Ziemer Ophtalmic). Também avaliamos a relação entre o diâmetro pupilar com o tempo da cirurgia e o tempo de ultrassom. Métodos: Estudo comparativo prospectivo, realizado no Centro de Excelência em Oftalmologia, Brasil. Foram incluídos 79 olhos de 67 pacientes com opacidade nuclear. Os mesmos foram divididos em Grupo Controle, que foi submetido a cirurgia de catarata com facoemulsificação manual, e Grupo Estudo, com catarata assistida por laser de femtossegundo. Todas as cirurgias foram realizadas pelo mesmo cirurgião experiente. Todos os pacientes receberam antiinflamatório não esteróide tópico no dia anterior à cirurgia e o mesmo colírio midriático no pré-operatório. Para quantificar o tamanho da pupila, as medidas foram realizadas usando um compasso cirúrgico: anterior ao procedimento de facoemulsificação e ao final da cirurgia. No grupo de estudo, medidas após o laser foram adicionadas. O tempo cirúrgico e o tempo de facoemulsificação também foram analisados. Resultados: Não foi encontrada diferença significativa entre o tamanho da pupila pré-femto x pré-faco (8,69 ± 0,44 mm x 8,63 ± 0,72 mm; p=0,643), bem como o tamanho da pupila no final da cirurgia (7,96 ± 0,98 mm x 7,78 ± 0,95 mm; p=0,480) e o tempo médio de cirurgia (p=0,780). No entanto, no grupo de catarata assistida por laser de femtossegundo, houve um aumento transitório do diâmetro pupilar após o laser, indicando uma tendência para maior variação no grupo femto. Conclusões: Embora o diâmetro pupilar fosse semelhante ao final da cirurgia, o grupo com catarata assistida por laser de femtossegundo apresentou maior variação intraoperatória da pupila. Portanto, para uma cirurgia de catarata assistida por laser de femtossegundo mais eficiente e segura, o cirurgião deve estar ciente do tamanho do diâmetro pupilar antes do procedimento.

18.
International Eye Science ; (12): 490-494, 2022.
Article in Chinese | WPRIM | ID: wpr-920438

ABSTRACT

@#AIM: To compare the consistency of angle Kappa and angle Alpha in age-related cataract eyes with three different instruments. <p>METHODS: Prospective study. Totally 60 eyes of 30 patients with age-related cataract from December 1 to December 30, 2020 were collected. After adapting to 10min in the darkroom before operation, the angle Kappa and angle Alpha were measured with iTrace, Lenstar 900 and IOL Master 700 biometric instruments, respectively. The difference and consistency of the three instruments were analyzed.<p>RESULTS: The results of angle Kappa measurement of iTrace, Lenstar 900 and IOL Master 700 were 0.25±0.13, 0.19±0.11, 0.21±0.11mm(F=1.903, P=0.155). The results of angle Alpha measurement of the three instruments were 0.31±0.11, 0.36±0.16, 0.36±0.14mm(F=2.999, P=0.052). The proportion of angle Kappa of the three instruments greater than 0.5mm is 3%, 2% and 2%, and the proportion of angle Alpha greater than 0.5mm is 5%, 15% and 22%. The distribution of angle Kappa and angle Alpha is mainly in the temporal side of both eyes. Compared with the angle Kappa distribution of both eyes, the temporal distribution ratio of angle Alpha is higher, and the distribution of angle Alpha measured by iTrace is closer than that of Lenstar 900 and IOL Master 700 along the horizontal line. There was a positive correlation between angle Alpha and angle Kappa measured by each instrument(r=0.2941, 0.4082, 0.5137; P=0.0226, P=0.0012, P<0.0001). The consistency of angle Kappa measurement results of three kinds of instruments was good, while that of angle Alpha measurement results was poor.<p>CONCLUSION: When making the decision of multifocal intraocular lens implantation before cataract surgery, the consistency of angle Alpha measured by Lenstar 900, IOL Master 700 and iTrace is poor, so it is necessary to compare and refer to the results of various instruments in clinical application. When the data of angle Alpha could not be obtained before cataract surgery, the angle Kappa measured with the three instruments could provide useful information for multifocal IOL implantation decision.

19.
Neuroscience Bulletin ; (6): 661-676, 2022.
Article in English | WPRIM | ID: wpr-929121

ABSTRACT

Measuring eye movement is a fundamental approach in cognitive science as it provides a variety of insightful parameters that reflect brain states such as visual attention and emotions. Combining eye-tracking with multimodal neural recordings or manipulation techniques is beneficial for understanding the neural substrates of cognitive function. Many commercially-available and custom-built systems have been widely applied to awake, head-fixed small animals. However, the existing eye-tracking systems used in freely-moving animals are still limited in terms of their compatibility with other devices and of the algorithm used to detect eye movements. Here, we report a novel system that integrates a general-purpose, easily compatible eye-tracking hardware with a robust eye feature-detection algorithm. With ultra-light hardware and a detachable design, the system allows for more implants to be added to the animal's exposed head and has a precise synchronization module to coordinate with other neural implants. Moreover, we systematically compared the performance of existing commonly-used pupil-detection approaches, and demonstrated that the proposed adaptive pupil feature-detection algorithm allows the analysis of more complex and dynamic eye-tracking data in free-moving animals. Synchronized eye-tracking and electroencephalogram recordings, as well as algorithm validation under five noise conditions, suggested that our system is flexibly adaptable and can be combined with a wide range of neural manipulation and recording technologies.

20.
Rev. bras. ter. intensiva ; 33(3): 412-421, jul.-set. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1347289

ABSTRACT

RESUMO Objetivo: Calcular as velocidades médias da dilatação de pupila para classificar a gravidade da lesão derivada da escala de coma de Glasgow, estratificada por variáveis de confusão. Métodos: Neste estudo, analisaram-se 68.813 exames das pupilas para determinar a velocidade normal de dilatação em 3.595 pacientes com lesão cerebral leve (13 - 15), moderada (9 - 12) ou grave (3 - 8), segundo a escala de coma de Glasgow. As variáveis idade, sexo, raça, tamanho da pupila, tempo de permanência na unidade de terapia intensiva, pressão intracraniana, uso de narcóticos, classificação pela escala de coma de Glasgow e diagnóstico foram consideradas confundidoras e controladas para análise estatística. Empregou-se regressão logística com base em algoritmo de classificação com aprendizado de máquina para identificar os pontos de corte da velocidade de dilatação para as categorias segundo a escala de coma de Glasgow. Resultados: As razões de chance e os intervalos de confiança desses fatores se mostraram estatisticamente significantes em sua influência sobre a velocidade de dilatação. A classificação com base na área sob a curva mostrou que, para o grau leve, na escala de coma de Glasgow, o limite da velocidade de dilatação foi de 1,2mm/s, com taxas de falsa probabilidade de 0,1602 e 0,1902 e áreas sob a curva de 0,8380 e 0,8080, respectivamente, para os olhos esquerdo e direito. Para grau moderado na escala de coma de Glasgow, a velocidade de dilatação foi de 1,1mm/s com taxas de falsa probabilidade de 0,1880 e 0,1940 e áreas sob a curva de 0,8120 e 0,8060, respectivamente, nos olhos esquerdo e direito. Mais ainda, para o grau grave na escala de coma de Glasgow, a velocidade de dilatação foi de 0,9mm/s, com taxas de falsa probabilidade de 0,1980 e 0,2060 e áreas sob a curva de 0,8020 e 0,7940, respectivamente, nos olhos esquerdo e direito. Esses valores foram diferentes dos métodos prévios de descrição subjetiva e das velocidades de dilatação previamente estimadas. Conclusão: Observaram-se velocidades mais lentas de dilatação pupilar em pacientes com escores mais baixos na escala de coma de Glasgow, indicando que diminuição da velocidade pode indicar grau mais grave de lesão neuronal.


ABSTRACT Objective: To calculate mean dilation velocities for Glasgow coma scale-derived injury severity classifications stratified by multiple confounding variables. Methods: In this study, we examined 68,813 pupil readings from 3,595 patients to determine normal dilation velocity with brain injury categorized based upon a Glasgow coma scale as mild (13 - 15), moderate (9 - 12), or severe (3 - 8). The variables age, sex, race, pupil size, intensive care unit length of stay, intracranial pressure, use of narcotics, Glasgow coma scale, and diagnosis were considered as confounding and controlled for in statistical analysis. Machine learning classification algorithm-based logistic regression was employed to identify dilation velocity cutoffs for Glasgow coma scale categories. Results: The odds ratios and confidence intervals of these factors were shown to be statistically significant in their influence on dilation velocity. Classification based on the area under the curve showed that for the mild Glasgow coma scale, the dilation velocity threshold value was 1.2mm/s, with false probability rates of 0.1602 and 0.1902 and areas under the curve of 0.8380 and 0.8080 in the left and right eyes, respectively. For the moderate Glasgow coma scale, the dilation velocity was 1.1mm/s, with false probability rates of 0.1880 and 0.1940 and areas under the curve of 0.8120 and 0.8060 in the left and right eyes, respectively. Furthermore, for the severe Glasgow coma scale, the dilation velocity was 0.9mm/s, with false probability rates of 0.1980 and 0.2060 and areas under the curve of 0.8020 and 0.7940 in the left and right eyes, respectively. These values were different from the previous method of subjective description and from previously estimated normal dilation velocities. Conclusion: Slower dilation velocities were observed in patients with lower Glasgow coma scores, indicating that decreasing velocities may indicate a higher degree of neuronal injury.


Subject(s)
Humans , Brain Injuries , Pupil , Biomarkers , Glasgow Coma Scale , Dilatation
SELECTION OF CITATIONS
SEARCH DETAIL